Des accidents mortels survenus dans des lacs font surgir la question de la sécurité électrique autour de l’eau

Electric Shock Drowning

Un accident récent au sujet d’une électrocution à quai a souligné les dangers du mélange eau et électricité. Dans le cas de cet accident, le courant électrique est entré dans l’eau à partir des bateaux ou des quais.  Dans cet article, 10 comportements sécuritaires à adopter par les plaisanciers qui vivent près de l’eau ou qui ont un bateau et certains spécifiquement pour les électriciens. 

The following article is the second in a 2-part series. The first article, triggered by the apparent electric shock drowning of 13-year-old Sarah Grace Tellifero, appeared in the September 16 issue of Electrical Industry Newsweek.

A recent incident involving a dockside electrocution underscores the dangers when water and electricity mix. In this instance, electrical current entered the water from boats or docks.  

“Wet environments are particularly dangerous when it comes to electricity. It’s vital to ensure electrical connections on or near the water are properly installed with appropriate safety equipment,” explains Molly Hall, Executive Director of the American Safe Electricity program. “Your loved ones’ lives just might depend on it.” 

Safety precautions for the public 

Share these tips with customers who live near water and/or have boats.

1. Properly maintain docks with electrical installations. Even so, it’s safest not to swim around docks with electrical power. “Prevent deadly shocks. Check your boats and docks,” Hall adds. “If you have not checked your boats and docks yet this year, don’t wait. Take the time to do so now.”

2. Never swim in or near marinas, docks or boatyards, say experts from the U.S. Electric Shock Drowning Prevention Association.

3. If you’re in the water and start to feel a tingle, swim away from any apparent electrical source and get out of the water as soon as possible without touching any metal objects (e.g., ladders). 

4. For bystanders hearing of a swimmer experiencing a tingle, immediately turn off power to everything you can. Do not jump in to help. You could easily become a casualty yourself.

5. Have your boat’s electrical system checked at least once a year. Also have your boat checked when something is added to or removed from its electrical system. If you are unsure about how to install something, do not call your neighbour/electrician friend. Call a certified electrician. There are some big differences between your house and your boat. Household wire is not suitable for use on boats as houses are motionless and generally dry. Even marine-rated wire that is not supported along its length will break with constant motion stress. Do NOT use wire nuts or splice connectors. Wire nuts are for solid conductor wire, which should never be on a boat, and splice connectors cut wire strands. Fuses are rated to protect the wire, not the stereo. If a fuse blows continuously, it should NOT be replaced with a larger one just to keep it from blowing again. Something else is wrong.

6. When boating or fishing, be aware of your surroundings and potential overhead electrical hazards. Ensure a distance of at least 10 feet between your boat and nearby power lines. Always lower masts of sail boats before using boat ramps.

7. Ensure your neighbour’s dockside electrical system complies with the Canadian Electrical Code and has been inspected. All electrical installations should be performed by a professional electrical contractor. Because docks are exposed to the elements, their electrical systems should be inspected at least once a year.

Safety precautions for electricians

The Brotherhood of Electrical Workers/National Electrical Contractors Association in the U.S. offers electricians the following tips: 

8. Ensure that all electrical installations comply, at a minimum, with articles 553 (residential docks) and 555 (commercial docks) of the 2011 National Electrical Code which mandates a GFCI on all dock receptacles. A GFCI measures the current in a circuit. An imbalance of that current, such as a discharge into the water, will trip the GFCI and cut off power.

9. Test the GFCI at least once a month or according to the manufacturer’s specifications. The GFCI should be located somewhere along the ramp to the dock so it can be easily found and tested by local fire departments as 9eeded. 

10. Ensure the metal frames of docks have “bonding jumpers” on them to connect all metal parts to a ground rod on the shore. This will ensure any part of the metal dock that becomes energized because of electrical malfunction will trip the GFCI or the circuit breaker.

 

Related Articles


Monde en mouvement

  • L’Ontario publie sa nouvelle vision d’un avenir énergétique abordable

    L’Ontario publie sa nouvelle vision d’un avenir énergétique abordable

    15-novembre-2024 CanREA applaudit le ministre de l’Énergie et de l’Électrification de l’Ontario pour sa vision et son engagement envers l’électricité abordable, fiable et propre  L’Association canadienne de l’énergie renouvelable (CanREA) félicite le gouvernement de l’Ontario pour son engagement envers l’électricité abordable, fiable et propre, engagement reflété dans sa vision L’avenir énergétique abordable de l’Ontario : l’argument pressant… Read More…

  • CanREA prête à travailler avec le nouveau gouvernement du Nouveau-Brunswick et son ministre responsable de l’Énergie

    CanREA prête à travailler avec le nouveau gouvernement du Nouveau-Brunswick et son ministre responsable de l’Énergie

    15-novembre-2024 CanREA félicite la première ministre Susan Holt, le Parti libéral du Nouveau-Brunswick et le ministre Legacy.  L’Association canadienne de l’énergie renouvelable (CanREA) félicite la première ministre Susan Holt et le Parti libéral du Nouveau-Brunswick pour leur élection en octobre, ainsi que René Legacy pour sa nomination, annoncée le 1er novembre, à titre de vice-premier ministre, ministre des Finances et… Read More…


Formation et événements

  • 15-novembre-2024 Par Shaina Hardie La Conférence destinée aux femmes de la FIOE qui a lieu deux fois par an a franchi une nouvelle étape en 2024. La conférence a réuni plus de 800 déléguées et délégués de partout en Amérique du Nord. Les sections locales de la FIOE du Canada ont été bien représentées et comptaient… Read More…

  • 10-novembre-2024 4 DÉCEMBRE 2024 | 1:00PM – 2:00PM EDT | EN LIGNE Rejoignez-nous pour ce webinaire organisé par le FCA-CAF et le CCRT. Écoutez les apprentis parler de leur formation et de leurs expériences en milieu de travail. Découvrez ce que nous pouvons faire de mieux pour soutenir les apprentis handicapés dans leur parcours de… Read More…